Commanding:
There are two types ot commands that can be issued to the system:
1. Control Commands
- To Arm the System in the Away Mode* (’)
- To Disarm the System* (t)
- To Bypass a Zone
- To Force the System to Accept a New Program Download
- To Shut DowrI Communication (dialer) Functions (non-payment of
monitormg fees m an owner’s system)
- To Shut Down all Security System Functions (non-payment for a
leased system)
- To Inhibit Local Keypad Programming (prevents takeover of your
accounts)
2. Status Commands
- To Cause the System to Upload a Copy of its Resident Program to
the central station
To Read System Status:
Arming Status
Ready Status and Current Faults
Presence of Alarms (pastor present)
Presence of Troubles (past or present)
AC Power Status
Bypass Status and Current Bypasses
*NOTES
1.If the system is programmed for open/close reporting by
user, User #7 will be reported.
2. After the4130XT and the 699 or PC have established valid
communication, each 4157 console displays an ‘OC’ sig-
nifying that It IS busy (occupied). Also, the 4130XT is not
responding to faults in its zones. The 4130XT will resume
the normal security tunctlons (mcludmg responding to faults
that look place during the downloading) after it is com-
manded to hang up See the 4130PC or 695-30XT instruc-
tions for details.
The detailed operation of the functions described below IS covered m the
Installation Instructions for the No. 695-30XT Program Cartridge and for
the 4130PC Download Software Diskette.
To Read List of Faulted Sensors
To Read List of Bypassed Sensors
- To Read 10 Day Alarm History Log
- To Read 10 Day Trouble History Log
- To Read List of Sensors Currently m Alarm
- To Read List of Sensors Currently in Trouble
Remote Communication Specifications:
.
Program Download Time 1 minute for a complete program
. Typical Total Time Including Call Up/Call-Back 3-4 minutes
Remote Command/Programming Advisory Notes:
Alarm and Trouble Reporiing are disabled during the time that the SYS-
tem and the central station are linked to each other for the described
functions, following a valid exchange of codes.
Keypad entries are ignored during the same time interval cited above.
. Should an alarm transpire during the remote program/control interval,
the system would not respond to the alarm condition untd the remote
mode was ended. The local zones and the Nos. 4190WH, 4192,
4194WH, 4196, and 4208 all store their fault conditions until they are
read by the Control, As such, alarm conditions from the local and
expansion zones would not be missed, only delayed.
. A copy of the program downloaded may be produced from either the
No, 699 Intelligent Programmer or the IBM PC compatible computer,
using those products’ internal report generators, when an optional prin-
ter is connected.