Spilt/Dual Reporting
Ademco Low Speed
Sescoa/Radionics
4+2 Reporting
Dual reporting (’51 ) sends all
reports to both primary and secondary phone
numbers. Split reporting allows reports to be divided between the phone numbers
according to the fields (1’34) selections. Split/Dual reporting can be selected by
enabling dual reporting and enabling one of the split reporting options in field
1
34. If option [1] is selected, all alarms, alarm restores and cancel repwts will go to
both phone numbers,
while all other reports will go to the secondary phone
number. If [2] is selected, open/close and test messages will go to both phone
numbers, while all other reports will go to the primary phone number. Folbwing are
the Split/Dual Reporting options:
Reporting
Field Number
Format
51 1*34 Where Reports Go
Dual
1 0 All reports to both num.
Split o lor2 1-alarm, alarm restore &
cancel to primary, all
others to secondary.
2=open/close, test to
secondary, all others to
primary.
Split/Dual 1 lor2 1-alarm, alarm restore &
cancel to both, all others
to secondary only.
2=open/close to both, all
others to primary only.
ADEMCO
LOW SPEED is a pulsed format which responds to a 1400 Hz
handshake and kiss-off, and transmits data with 1900Hz pulse tones @ 10
pulses per second (pps), A typical message consists of two rounds which must
be verified by the receiver. A complete standard report consists of either a 3 or 4-
digit account number followed by a 1-digit alarm code. Though 2 rounds are sent,
only the valid report is displayed.
In expanded reporting, two messages are sent, two rounds per message, the first
being the account number and alarm cwde, the second being the zone ID code to
which the alarm was assigned. A complete expanded report consists of a 3 or 4-
digit account number followed by a 1-digit alarm code, then the alarm code is
repeated, followed by the channel number.
EX. Standard:
CCCC E where: CCCC = account number
Expanded:
CCCC E
E = event code
EEEE Z Z = zone ID code
Standard and expanded reporting in the SESCOA/RADIONtCS format is virtually
the same as ADEMCO Low Speed except for the following:
1, The handshake and kiss-off frequency is 2300 Hz.
2. The data is transmitted with 1800 Hz pulse tones.
3. The rate of transmission is 20 pps.
A 4+2 report consists of a 4-digit account number and a 2-digit alarm code, or
event code. 4+2 reports can be accomplished either in ADEMCO Low Speed (1O
pps), or SESCONRADIONICS (20 pps) format.
In 4+2 reporting a unique 2-digit code for each zone is reported. A 4-digit
account number followed by a 2-digit code is sent, where the first digit is the
actual event, such as in ALARM, RESTORE, or TROUBLE, etc., and the second
digit of the code represents the “zone” where the event occurred. (but not
necessarily the actual zone number). Each code in itself is unique to a specific
zone. If desired, the actual zone number can be reported by entering the
corresponding 2-digit zone number (ex. zone
1= [0] [1]; zone 63= [6] [3]). A
report might appear as:
1 234 59 (“5 9“ might be a unique “TROUBLE RESTORE, ZONE 25).
-49-