VOLTAGE TRIGGERS (Connector J7)
(Ground Start Module, Keyswitch, Remote Console Sounder)
General Information
Connector J7, located on the right hand side of the main PCB provides 4 trigger
outputs for operating the 675 Ground Start Module, the 4146 Keyswitch, a
remote console sounding piezo, and for triggering auxiliary alarm signaling
equipment (such as the 7720 and 7920SE LORRA Subscriber Radios). Note that
these output triggers can be enabled by partition via programming field 2*20.
The pin assignments of this connector are shown below. Use only the 4142TR
9-wire cable (available as an option) for making connections to this connector,
output 1
J7 CUNNCCTON
outputs 2 & 4
OUT !: GROUNO START OR OPENJCLOSE
OUT 2. FIRE OR KEYSWITCH ARMED LEO
OUT 3. BURGLAtW/AUOISLE PANIc/AuxILIARY
OUT 4; SILENT PANICIOURESS OR KEYSWITCH READY LEO
Output 2,3 &4 Rating:
Ground Start Module
Not intended for use In
UL Listed anplicatlons.
Operates, by default, as a trigger for the 675 ground
start module.
This output may optionally be
programmed to operate as an operdclose trigger or as a
remote console sounder output. Only one of these
options may be used at any time.
Rating:
When Activated: 10 -13.8 VDC through 4K
ohms
(2.5MA max)
When De-activated: 100 ohms to ground
Operate, by default, as Fire and Silent Panic/Duress
triggers respectively. These triggers may optionally be
programmed to act as Arm and Ready status indicators
when it is desired to use the 4146 keyswitch.
When Activated: 10- 13.8 VDC through 5K ohms
(2MA max)
When De-activated: 1k ohms to ground
An optional 675 Ground Start module can be used for installations having
telephone lines which require ground start instead of loop start operation to
obtain dial tone from the telco central office.
If used, program field 146 must be set to “O” (factory default) and the 675
Ground Starl Module must be connected to the panel’s J7 connector trigger
output 1, to auxiliary power, and to the “RING” side of the telephone line as
shown in the diagram below.
Use the following procedure to determine which side of the telephone line is the
“RING side:
a. Connect the “+” lead of a DC voltmeter to earth ground, and the “-” lead to
one side of the telephone line.
b. The wire which reads +50VDC is the “RING” side,
When the panel has a message to transmit to the central station, it will seize the
line, go off hook, and then trigger the 675 module to connect the “RING” side of
the telephone line to earth ground. The panel will cause the module to break the
connection between “RING” and earth ground when a dial tone is obtained.
4147TR CALIIJ
.17 C0NNEl,70n
e
,
1
‘Q%+b
:0”
mTouNO START
TRIGGER
GnAY
.
47$
71LUE
Q+
,
OROuNo
STAR
YELLOW
.
MODU..
—–—
BLACK
“+0
TERMINAL r
(CUT QUANGE
-i+
WHITE
JUMPER)
%.
.
$ $
RT
,, . ~ TO AUXPOWER -
~40,
l+#~::~g::;ORAw‘:O:N :
To TELCO To EARTH
RING
GROUND
1) OUT 1 IS NO LONGER
USABLE FOR OPEWCLOSE
Hi
BROWN
!SEE FIELD 1, 46).
Q90
.
2) OUT 2,3,4 CAN STILL BE
%0
uSED TO PROVIDE
ALARM
BLUE
STATUS INDICATIONS OR
%,
e
TO OPERATE A KEYSWITCH
(SEE FIELD 15).
,
3) THE 675 IS NOT UL LISTED
BLACK
m
-23-
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare