VISTA-250FBP (3/17/2003) 13850 - 4
Detection and Alarm
(5) Each RPM (Remote Point Module) enclosure shall be
tamper protected.
b. Wireless Expansion – The control shall support up to 250 wireless
zones using a 5800 series RF receiver (fewer if using hardwire
and/or polling loop zones). Wireless zones shall have the
following characteristics:
(1) Supervised by control panel for check-in signals (except
certain non-supervised transmitters).
(2) Tamper-protection for supervised zones.
(3) Individually assignable to one of eight (8) partitions.
(4) Individually assignable to bell outputs and/or auxiliary
relays.
(5) Support wireless devices listed for Commercial Burglary
using the 5881ENHC RF Receiver.
3. Partitions – The control shall provide the ability to operate eight (8)
separate areas, each functioning as if it had its own control. Partitioning
features shall include:
a. A Common Lobby partition (1-8), which can be programmed to
perform the following functions:
(1) Arm automatically when the last partition that shares the
common lobby is armed.
(2) Disarm when the first partition that shares the common
lobby is disarmed.
b. A Master partition (9), used strictly to assign keypads for the
purpose of viewing the status of all eight (8) partitions at the same
time (master keypads).
c. Assignable by zone.
d. Assignable by keypad/annunciator.
e. Assignable by relay to one or all eight (8) partitions.
f. Ability to display fire and/or burglary and panic and/or trouble
conditions at all other partitions’ keypads (selectable option).
g. Certain system options selectable by partition, such as entry/exit
delay and subscriber account number.
4. User Codes – The control shall accommodate 250 user codes, all of which
can operate any or all partitions. Certain characteristics must be assigned
to each user code, as follows:
a. Authority level (Master, Manager, or several other Operator
levels). Each User Code (other than the installer code) shall be