VISTA-250FBP (3/17/2003) 13850 - 9
Detection and Alarm
(2) Sescoa/Radionics.
(3) ADEMCO Express.
(4) ADEMCO High Speed.
(5) ADEMCO Contact ID.
b. Backup reporting The system shall support backup reporting via
the following:
(1) Secondary phone number.
(2) ECP long-range radio (LRR) interface.
(3) Option to select long range radio (LRR) or dialup as the
primary reporting method (dynamic signaling feature).
c. Internet reporting The system shall be capable of communicating
with the central station via the internet using Alarmnet-i. It shall
provide the user with the ability to control the system via a browser
interface (i.e., AOL, Netscape, Internet Explorer). All packet data
transmitted to the monitoring station shall be encrypted with a
minimum of 1024 bits of encryption.
20. Audio Alarm Verification Option - Provides a programmable Audio
Alarm Verification (AAV) option that can be used in conjunction with an
output relay to permit voice dialog between an operator at the central
station and a person at the premises.
21. Cross-Zoning Capability - Helps prevent false alarms by preventing a zone
from going into alarm unless its cross-zone is also faulted within 5
minutes.
22. Pager Interface The Control Panel shall be capable of sending event
information to an alphanumeric pager via a pager interface device.
23. 24-Volt Power Supply The Control Panel shall be compatible with a 24-
Volt power supply module. The module shall supply two (2) 24 vdc, 3.4
amps, rectified, unfiltered outputs, which power:
a. Alarm notification appliances, including but not limited to sirens
horns, bells and strobes.
b. Auxiliary devices capable of operating using full-wave rectified
unfiltered voltage.
24. Exit Error False Alarm Prevention Feature The System shall be capable
of differentiating between an actual alarm and an alarm caused by leaving
an entry/exit door open. If not subsequently disarmed, the control panel
shall: