TESTING THE BURGLARY
SYSTEM
(TO BE CONDUCTED WEEKLY)
Using the
5
TEST Key
The TEST key puts your system into the Walk Test mode, which
allows each protection point to be checked for proper operation.
1. Disarm the system and close all protected windows, doors,
etc. READY should be displayed.
TEST
2. Enter your security code and press the 5 key.
3. The external sounder should sound for 3 seconds and then
turn off. If the sounder does not sound, it may be due to
dialer communication activity. Wait a few minutes and try
again. If the sounder still does not sound, CALL FOR
SERVICE IMMEDIATELY.
4. The keypad will sound a single beep every 15 seconds as a
reminder that the system is in Test mode.
Note that no alarm reports will be sent to the central
monitoring station while the system is in Test mode.
5. Open and close each protected door and window in turn and
listen for three beeps. The identification of each faulted
protection point should appear on the display.
6. Walk in front of any interior motion detectors (if used) and
listen for three beeps as movement is detected. The
identification of the detector should appear on the display
when it is activated. If a problem is experienced with any
protection point (no confirming sounds, no display), CALL
FOR SERVICE IMMEDIATELY.
7. Turn off Test mode by entering the security code and
pressing the OFF key.