‘VIEWING CAPABILITIES
OF A USER
VIEWING
DOWNLOADED
MESSAGES
USING THE BUILT-IN
USER’S GUIDE
DISPLAYING
DESCRIPTORS
PANIC KEYS
Enter a security code + [*] + [*] to view the user ID number and the authority
level for that code. These items will typically be displayed as follows:
-
The user’s OpetiClose repod capability is shown by the dot following the
authority level. If Open/Close is not enabled for a user, the dot will not appear.
Users may occasionally receive messages on the console display from their
installation company. Whenthis omurs, theconsole will display ’’Message. Press
Ofor5secs.”. instruct theuser topress andhold the Okeytodisplay the central
station’s message. Note that the system must be in the READY state to view
these messages.
An abbreviated User’s Manual is stored in the system’s memory, and can be
patiicularly useful to the end user if the ptinted User’s Manual is not conveniently
accessible when the user needs to peflorm a seldom used and unfamiliar system
procedure. The Built-in User’s Guide is displayed by simply pressing any of the
function keys (e.g., OFF, AWAY, STAY, MAXIMUM, BYPASS, INSTANT, CODE,
TEST, READY, #, and CHIME) for approximately 5 seconds and then releasing it.
Abbreviated instructions relative to the key that has been pressed will then be
displayed (2 lines of text are displayed at a time). This function is available when
the system is in the armed or the disarmed state.
The Alpha Consoles candisplay allprogrammed descriptors, which is useful to
the installer when checking entties, and can be helpful to the user when there is a
need to identify zones. Todisplay descriptors, press and hold the READY key
until the built-in instructions for that key appear, then release the key. The zone
descriptors will appear one at a time, for about 2-3 seconds each. For faster
viewing, press the READY keyto display the next descriptor in numerical order
and soon. When alldescriptors have been display ed, the Control will exit display
mode. Toexitdisplay mode before alldescriptors have been display ed, enter the
security code and press the OFF key.
There are three pairs of keys (~ + 1], [# + 3], ~ + #]) that, if programmed, can be
used to manually initiate alarms and send a repofl to the central station. Each pair
of keys can be individually programmed for24Hour Silent, Audible or Auxiliaw
(Emergency) responses. Thepanic function inactivated when theapproptiate
pair of keys are pressed at the same time.
The panic functions are identified by the system as follows:
PANIC PAIR
Dis~laved as 7
one
‘+1 95
#+3
96
“+#
99
These panic keys can also be programmed with an alpha descriptor.
IMPORTANT: For the Panic functions to be of practical value, the system must be
connected to a central station.
—.
-37-