Changing Codes
The system can support up to 8 separate user codes.
MASTER CODE: User 1.
The Master Code (User 1) can be changed:
1. Enter Master Code (e.g. 1234)
2. Press 8/ (CODE)
3. Press 1 (User 1)
4. Enter new User Code (e.g. 5678). Two beeps confirms code acceptance.
PROGRAMMING OTHER USER CODES INTO THE SYSTEM
The Master Code is used to programme new User Codes into the system:
1. Enter Master Code (e.g. 5678).
2. Press 8/ (Code).
3. Press 2 (User 2).
4. Enter User 2 Code (e.g. 4321).
Users can programme their own new User Codes into the system:
1. Enter User Code (e.g. 4321).
2. Press 8/ (Code).
3. Press 2 (User 2).
4. Enter new User 2 Code (9876).
DELETING USER CODES
Any user may delete their own code by entering their CODE + 8 + USER No + Ö:
1. Enter User 2 Code (e.g. 9876).
2. Press 8/ (Code).
3. Press 2 (User 2).
4. Press Ö.
Note: The MASTER CODE can delete any USER CODE.
DURESS - User Code 8/ may have been reserved for a DURESS CODE. This
type of code can perform all normal system functions, but will send a silent
DURESS Signal to your monitoring station
LCD KEYPAD PROGRAMMING
Setting the System
FULL SET
To FULL SET the system:
1. Enter the User Code.
2. Press 1/ (Full Set).
A constant exit tone will sound. During the exit period, the DAY LCD symbol
will flash and the exit tone will become broken as the user passes detectors
on the exit route. The exit tone will become constant, when the last detector on
the exit route has been passed. Two confirmation beeps indicate that the system
has set.
Note: To stop the system from setting during the exit period press Ö. When
the system has set, Ö will no longer function. Press # + 1 / (Full
Set) to EASY SET the system, if available.
PART SET
Selected areas will set using the Part Set function. The engineer will programme
which selected areas will set with user approval, (see System Settings).
To PART SET the system:
1. Enter the User Code.
2. Press 2/ (Part Set).
A constant exit tone will sound. During the exit period, the DAY LCD symbol
will flash and the exit tone will become broken as the user passes detectors
on the exit route. The exit tone will become constant, when the last detector on
the exit route has been passed. Two confirmation beeps indicate that the system
has set
Note: To stop the system from setting during the exit period press Ö.
When the system has set, Ö will no longer function.
Press # + 2/ (Part Set) to EASY SET the system, if available.