+12 volts when armed
10. Duress Digit
space protection devices.
The duress digit is a change to the last digit of the security code.
Its purpose is to dllow someone to initiate a silent panic condition
but still give the impression that the control'is working nonally.
For example,
if the security code is 1234 and the duress digit is
5, entering 1234 will cause the system to disarm, but entering 1235
(assuming one is in a hostage situation) will cause the system to
disarm, but will also trigger the communicator to send a silent panic
message.
MJTE: If the user of the system inadvertently programs a secondary
security code that is the same as the master code, but has the
same last digit as the PR@4 programed duress digit, the duress
silent panic capability is suppressed to avoid the transmission
of false alarms to the central alarm monitoring service.
Il.
12.
13.
14.
Security Cade
This 4 digit code restricts the use of the system to only those who
know the code.
Any digits, including repetitions, may be chosen.
There are two such codes.
One is PROM programmed at installation
and the second is user changeable from a keypad at any time, using
the master code to enable the change.
Forced
Arming Enable
Forced arming allows a user to arm the system even though certain
zones are in a faulted condition. Such faulted zones will be shunted
.by depressing BYPASS to override the fail safe arming during'the aming
period.
Forced arming must be PROM enabled for each zone in which
it is desired (with critical zones, such as safes for instance, arming
of the syste+&hould be prevented when a faulted condition exists).
Bypass
Enable
Zones in the system may be individually bypassed from the Security
Console or Remote Keypad during the disarmed period. This option
allows the user to bypass zones that should be ignored, whether or
not they are faulted at arming time (In this manner, "Swingers" may
be ignored or a loading dock door that must be later opened can be
left unsecured). To allow individual zone bypass, each such zone
must be PROM enabled for 'this option.
20~ Restore En&de
As shipped, the system has all zones set up as non-restore zones.
Non-restore means that once a zone has gone into alarm during the
arming period,
subsequent faults of that zone will not trigger a
new alarm. The zone is effectively "locked-out", preventing multiple
false alarms in the event of a "Swinger".
Zones that have been PROM selected as restore'zones will allow the
bell/siren to sound more than once if the zone returns to nonnal
and faults again after the bell/siren has timed out.
628-6