3.
Still at subscriber 85890, following the events of example 2 above, channel
2 restores (initiating the call) and channels 5 and 6 remain in alarm:
Subscriber
Channel Number
Xdentification'
1234
5678
9
Message:
5890
5355
6655
7
Channel 2:
MW RESTORE
Channels 5,6:
PREVIOUSLY REPORTED ALARMS
(still in effect)
4.
Subscriber #0135 sends an opening:
Subscriber
Channel &mber
Identification
1234
5678
9
Message:
0135
1222 2222
2
Channel
1:
USER ID - User #l opened
Channels 2-9:
OPENING REPORT TRANSMITTED
5.
After transmission of Example 4, subscriber #0135 sends a closing:
Subscriber
Channel kmber
Identification 1234 5678
9
Message:
0135 1444
4444
4
Channel
1:
USER
ID -
User
81
closed
Channels 2-9: CLOSING REPORT TRAMMITTED
6. Subscriber #0135, User
#l
force arms the system, causing faulted zone
2 to be shunted (for the sake of this example, Zone 2 = Channel 2, not
a requisite). *
Subscriber
Identification
Message:
0135
0135
Channel kmber
1234 5678
9
1444
4 4 4 4
4 (Closing Report)
5155 5 5 5 5
3 (Shunt Report)
E:
Shunt reports always
are shunted.
If indiv
to arming, the shunt
was armed and the clos
accompany closing reports when burglary zones
idual zone shunting had been performed prior
reports would be sent later when the system
ing report sent.
If
a 24 hour zone (e.g. fire,
panic) were to be individually shunted (if permitted by installer
PROM option), the shunt report depicted below would be transmitted
inxnediately.
The example below shows a shunt report for Zone.5.
Subscriber
Channel l@mber
Identification 1234 5678 9
Message:
0135
5555 1555 3
Shunt restorals are
not
transmitted for burglary zones as these zones are known
to have been restored when the system is disarmed and the opening report is
transmitted.
Shunt restorals are transmitted for 24 hour zones, however, when
the restoral takes place.