VISTA-128BP/VISTA-250BP Installation and Setup Guide
3-24
Using the 4100SM
To connect a serial printer using the 4100SM, refer to
Figure 3-33
and perform the following steps:
Step
Action
1
Connect terminal 23 on the control panel to
terminal 3 on the 4100SM.
2
Connect terminal 6 on the 4100SM to the
Brown wire on the 4142TR cable.
3
Connect the 4142TR cable to J8 on the
control.
4
Connect terminals 8 and 7 of the 4100SM to
terminals 6 and 7 (aux. power (+) and (-)),
respectively of the control.
5
Connect the UL EDP Listed serial printer to
the 4100SM Interface Module.
The 4100SM Module is supplied with a 10-
foot RS232 cable. A longer cable can be used
if the VISTA-128BP/VISTA-250BP is
separated from the serial printer by more
than 10 feet, but the total cable length should
be less than 50 feet.
123456789
NU
J8 CONNECTOR
VIOLET
GREY
YELLOW
RED
GREEN
BROWN
BLUE
BLACK
IN 2
IN 3
GROUND
OUT 5
OUT 6
GROUND
GROUND
PRINTER DTR
4142TR CABLE (SUPPLIED WITH 4100SM)
8
7
6
5
4
3
2
1
4100SM SERIAL MODULE
+ PWR
- (GND)
RXD
not used
not used
TXD
not used
DTR
BLUE WHITE
To TB6 Aux. Power (+)
(25mA current draw)
To TB7 Aux. Power (-)
USE GENDER CHANGER
SUPPLIED WITH 4100SM
IF PRINTER HAS DB25
MALE CONNECTOR
3M
Cable
Supplied with
4100SM
SERIAL PRINTER
SET FOR: 8 DATA BITS
EVEN PARITY
STOP BIT
300/1200 BAUD
4100SM JUMPERS
(CUT TO SET RESPECTIVE SIGNAL FLOATING)
COLOR FUNCTION PIN #
RED
BLUE
WHITE
CD
CTS
DSR
8
5
6
RED
4100SM-011-V0
Figure 3-33: Printer Connections to the 4100SM
NOTE:
See the 4100SM Installation Instructions for
details concerning the serial printer operation.
Installing the 4285/4286 VIP Module
The 4285/4286 VIP Module is an add-on accessory that
permits the user to access the security system (and
relays) via a TouchTone telephone. This may be done
either from the premises or by calling the premises
from a remote location. Only one VIP Module can be
used in a security system. This module must be
enabled as Device Address 4 in the
Device
Programming
in
#93 Menu Mode
, and must be assigned
to a partition.
U
L
The 4285/4286 VIP Module is not permitted in
UL installations.
Detailed operating instructions for phone access
to the security system are provided with the VIP
Module.
The 4285/4286 VIP Module features:
Allows the user to receive synthesized voice
messages over the phone regarding the status of
the security system.
Allows the user to arm and disarm the security
system and perform most other commands using
the telephone keypad.
Allows the user to control relays using the
telephone keypad.
Provides voice annunciation over the phone to
confirm any command that is entered.
Announces many of the same words that would
normally be displayed on an alpha keypad under
the same system conditions. Refer to the words in
bold on the Alpha Vocabulary list found in the
#93
Menu Mode
in the
Programming Guide
.
Can be supervised for connection to control panel
(annunciated and reported as Zone 804).
The 4285/4286 is wired between the control panel and
the premises handset(s) (see
Figure 3-36
). It listens for
TouchTones on the phone line and reports them to the
control panel. During on-premises phone access, it
powers the premises phones. During off-premises phone
access, it seizes the line from the premises phones and
any answering machines.
The VIP module will not operate until the
device address (04) is enabled in the controls
Device Programming
in
#93 Menu Mode
.
Do not mount the VIP Module on the cabinet
door or attempt to attach it to the PC board.
To install the VIP module, perform the following steps:
Step Action
1 Mount the module in the control cabinet if
space is available or, if this is not possible, on
the side of the cabinet or adjacent to it.
If you mount the VIP Module inside the
control cabinet,
attach it to the cabinets
interior surface with 2-faced adhesive tape.
You may leave the modules cover off if it is
mounted within the cabinet.
If you mount the module outside the
cabinet,
use the screw holes at the rear to
mount horizontally or vertically (2-faced
adhesive tape may be used, if preferred).
2 Affix the 4285/4286 connections
label
(supplied separately) to the inside of the VIP
Modules cover, if the cover is used.
Otherwise, affix the label to the inside of the
control cabinets
door.