ADEMCO VISTA-50PEN Betriebsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 84
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
23
Accessing Other Partitions (contd)
Master Keypad Operation
A "Master" keypad is one that reflects the status of the entire system
(Partitions 1-8) on its display. This is useful because it eliminates the
need for a security officer in a building to have to "log-on" to various
partitions from one partition's keypad to find out where an alarm has
occurred.
A description of a typical display follows:
SYSTEM 1 2 3 4 5 6 7 8
STATUS R R N N A T
B
The status of each partition is directly below the partition number on
the display. Possible status indications include:
A = Armed Away M = Armed Maximum
S = Armed Stay I = Armed Instant
R = Ready N = Not Ready
B = Bypassed/Ready
= Alarm Memory/Trouble present
To obtain more information regarding a particular partition, enter [*]
+ [Partition No.] (i.e.,
4). This will allow viewing
only
of that
partition. In order to affect that partition, the user must log on with a
code that has access to that partition. Also, in order for a user of any
partition to log onto the "Master" partition (Partition 9) to view the
status of
all
partitions, that user must have access to all partitions.
Otherwise, access will be denied.
The following is an example of what would be displayed for a fault
condition on Zone 002 (Loading Dock Window) on Partition 1
(Warehouse) when logging on from a keypad on Partition 9:
WHSE DISARMED
HIT
FOR FAULTS
This is the normal display that appears at Partition 1's keypad(s).
Pressing
will display:
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 83 84

Kommentare zu diesen Handbüchern