*51 DUAL REPORTING [0]
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),
alarms and alarm restores go to both primary & secondary
numbers, while all other reports go to secondary only. If used
with Split Reporting "2" option, alarms and alarm restores go to
both, open/close and test messages go to secondary only, while
all other reports go to primary. If used with Split Reporting "3"
option, fire alarms and fire supervisory signals go to both
primary and secondary , while all other reports go to secondary
only.
*52 STANDARD/EXPANDED REPORT FOR PRIMARY
[0]
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
0=standard; 1=expanded; Note: Expanded overrides 4+2 format.
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
[0]
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
0=standard; 1=expanded; Note: Expanded overrides 4+2 format.
ZONE TYPE RESTORE ENABLES
1=enable; [0=disable]
*79 FOR ZONE TYPES 1-8 *80 FOR TYPES 9/10
1 234 56 78 9 10
*83 FIRST TEST REPORT TIME | | |
[Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-59;
00 in all boxes=instant (Day 01= Monday)
*84 SWINGER SUPPRESSION Partition-Specific
*85 ENABLE DIALER REPORTS Partition-Specific
FOR PANICS & DURESS
*87 ENTRY WARNING Partition-Specific
*88 BURG. ALARM COMM. DELAY Partition-Specific
*89 RESTORE REPORT TIMING [0]
0=instant; 1=at bell timeout; 2=at diarm. Must be "0" for fire or
UL Installations.
*90 2nd SUBS. ACCT # | | | |
1*17 LOBBY PARTITION [0]
Enter the "common lobby" partition (1-8)
1*18 AFFECTS LOBBY Partition-Specific
1*19 ARMS LOBBY Partition-Specific
1*20 EXIT ERROR LOGIC [0]
0=No, 1=Bypass E/E and Interior zones faulted after
exit delay. Must be "0" for UL Commercial Burglary.
1*21 EXIT DELAY RESET [0]
0=No; 1=Resets Exit Delay to 60 seconds after
zone is closed. Must be "0" for Commercial Fire and UL
installations.
FIELDS 1*22-1*25: Allow four sets of two zones each to be
linked so that both must fault within a five minute period to
cause an alarm. Must be 0 for UL Burglary.
1*22 CROSS-ZONING PAIR ONE | | | |
1*23 CROSS-ZONING PAIR TWO | | | |
1*24 CROSS-ZONING PAIR THREE | | | |
1*25 CROSS-ZONING PAIR FOUR | | | |
MISCELLANEOUS WIRELESS OPTIONS
Fields 1*28 - 1*32 are not applicable to Commercial
Fire or UL installations.
1*28 RF TX LOW BATTERY SOUND [0]
1=immediate; 0=when disarmed.
1*29 RF TX LOW BATTERY REPORT ENABLE [0]
1=enable; 0=disable
1*30 RF RCVR CHECK-IN INTERVAL [06] |
02-15 times 2 hours; 00 disables supervision.
1*31 RF XMiITTER CHECK-IN INTERVAL [12] |
02-15 times 2 hours; 00 disables transmitter supervision.
1*32 RF RECEIVER TYPE [0]
1=4281; 2=5881
1*33 TOUCH-TONE W/ROTARY BACKUP [0]
1=enable; 0=disable
1*34 COMM. SPLIT REPORT SELECTION [0]
0=no; 1=alarms and alarm restores primary, others
secondary; 2=open/close, test secondary, others primary; 3 =
fire alarms & troubles primary, all secondary. See 51 for
comments if using with dual reporting.
1*42 CALL WAITING DEFEAT [0]
1=Yes; 0=No.
1*43 PERM. KEYPAD BACKLIGHT
Partition-Specific
1*44 WIRELESS KEYPAD [0]
TAMPER DETECT ENABLE 1=enable; 0=disable
Must be "0" for Commercial Fire & UL installations.
1*45 EXIT DELAY SOUNDING
Partition-Specific
1*47 CHIME ON BELL 1
Partition-Specific
1*48 WIRELESS KEYPAD ASSIGNMENT [0]
0=disable; enter partition in which RF keypad used, 1-8.
Must be "0" for Commercial Fire & UL installations.
1*49 SUPPRESS TX SUPERVISION SOUND [1]
1=disable; 0=enable. Must be "0" for Commercial Fire & UL
installations.
1*52 SEND CANCEL IF ALARM + OFF Partition-Specific
1*53 DOWNLOAD CALLBACK [0]
1=callback not required; 0=callback required; Must be "0" for
Commercial Fire & UL installations.
1*57 5800 RF BUTTON GLOBAL ARM [0]
Enter "1" to have the system arm/disarm following the button
user's global arm settings. Enter "0" if the button is not to be
used to global arm the system. Must be "0" for Commercial
Fire & UL installations.
1*58 5800 RF BUTTON FORCE ARM [0]
Enter "1" to enable. If a zone is faulted after pressing button,
console will beep once. User should press button again within
4 sec. to force bypass those zones. Enter "0" to disable.
Must be disabled for UL Listed installations.
1*60 ZONE 5 AUDIO ALARM VERIFICATION [0]
Enter 1 If 2-way audio (AAV) is being used; Enter 0 if it is not.
Must be "0" for Commercial Fire & UL installations.
1*70 EVENT LOG TYPES
1=enable; 0=disable Alrm Chck Byps O/C Syst Test Rpt
1*71 12/24 HOUR TIME STAMP FORMAT [0]
0=12 hour; 1=24 hour
1*72 EVENT LOG PRINTER ON-LINE [0]
0=disable; 1=enable