VIII. TESTING THE SYSTEM
USING TEST MODE
After the installation is completed, the Security
System should be thoroughly tested as follows:
1.
With the System in the disarmed state, check
that all zones are intact. If DISARMED - Press ~]
to show faults (5137) or NOT READY (4137) is
displayed, press the ~] key to display the
descriptors of the faulted zone(s). Restore faulted
ZOne(S) if necessary, 60 that “S* DISARMED***
READY TO ARM (5137) or READY (4137) is
displayed.
2. Enter the security code and press the TEST
key. The external sounder (if used) should 6ound for
3 seconds and then turn off (the system is
operating on the back-up battery only at this time).
NOTE 1. The system will not enter the Test mode if
the battery voltage is too
low, if the battery is not
connected, or if any communication messages are
waiting to be transmitted.
NOTE 2. As a reminder that the system is in the
Test mode, the Console will sound a single beep at
15-second intervals if no protection zones are
violated.
NOTE 3. In the Test mode, no alarm reports
will be
sent to the central station. Also, the external
sounder (if
used) will not be activated.
Doore nd windows
Open and close each protected door and window in
turn. Each action should produce three beepa from
the Console. The descriptor for each protection
zone will appear on the Console di6play.
Motion detectors
Walk in front of any interior motion detectors.
Listen for three beeps when the detector senses
movement. While it is activated, its descriptor will
remain displayed on the Console.
Note tha~
wireless PIRs will have a 3 minute lockout between
transmissions to conserve battery life.
Smoke detectors
Follow the test procedure provided by the
manufacturer of each smoke detector to ensure that
all detectors are operational and are functioning
properly.
NOTE: A 2-wire smoke detector display will not
clear until the Test mode is exited.
Turning off TEST mode
Enter the security code and press the OFF key.
ARMED SYSTEM TEST
IMPORTANT! A message will be sent to the
central station during the following tests. Notify
the central station that a test will be in progress.
NOTE: A display of “COMM. FAILURP (Alpha
consoles) or “Fe (Fixed-Word consoies) indicates a
failure to communicate (no Kissoff by the receiver
a! the central s~tion after the maximum num~r of
transmission attempts is tried).
1.
Arm the system and fault one or more zones.
Silence alarm sounder(s) each time by entering the
code and pressing OFF. Check that Entry/Exit delay
zones provide the assigned delay times.
2. Check the keypad-initiated alarms, if
programmed in field “05, by pressing the Panic
keys (“ and #, 1 and
, and/or 3 and #). If the
system has been programmed for audible
emergency, the console will emit a loud, steady
alarm sound. The word ALARM and a descriptor
“99- will be displayed for
and #. (if 1 and are
pressed, a ’95” will be displayed; if 3 and # are
pressed, a “96” will be displayed).
Silence the
alarm by entering the security code and pressing
OFF. If the system has been programmed for silent
panic, there will be no audibie alarms or displays. a
report will be sent to the central station, however.
3. Notify the central station that all tests are
finished and verify results with them.
TURNING THE
SYSTEM
OVER TO THE USER
1. Fully explain the operation of the system to the
user by going over each of ita functions as well as
the User’s Manual supplied.
2. In particular, explain the operation of each
zone (entry/exit, perimeter, interior, fire, etc.).
Be sure the user understands how to operate any
emergency feature(s) programmed into the system.
IMPORT ANTI: In the spaces provided in the
Users Manual, record the Entry and Exit Delay
time6,
and those functions that have been
programmed into the available paira of PANIC keys
(* and #, 1 and
, 3 and #).
3. Make sure the user understanda the importance
of testing the system at least weekly, following the
procedure provided in the User’s Manual.
-16-