- 7 -
TO DETERMINE TOTAL STANDBY LOAD
ON BATTERY, ADD 100mA TO TOTAL OF
AUX. POWER OUTPUT AND REMOTE
KEYPAD CURRENTS.
4 6 8 10 11 13 16 17 18 19 20
21
EARTH GROUND
SEE INSTRUCTIONS
FOR PROPER GROUNDING
TELEPHONE WIRING
(VIA RJ31X* JACK DIRECT
CONNECT CORD)
*IN CANADA, CA38A JACK
BLACK: KEYPAD GROUND (–) RETURN
RED: KEYPAD PWR (+)
GREEN: DATA IN FROM KEYPAD
YELLOW: DATA OUT TO KEYPAD
AUX. POWER
OUTPUT
10.5-13.8VDC
500mA MAX.
INTERRUPTS
FOR FIRE
ALARM RESET
NOTE:
KEYPAD
CURRENT MUST
BE INCLUDED IN
AUX. CURRENT
DRAIN
CALCULATIONS
BATT E RY
12V, 4AH
OR 12V, 1.2AH
+
+
CONNECTOR TABS
USE UL LISTED
LIMITED ENERGY
CABLE FOR ALL
CONNECTIONS
FOR COMPLETE
INFORMATION, SEE
INSTRUCTIONS
N5478V5
PLUG-IN TRANSFORMER
16.5VAC, 25VA
(e.g. ADEMCO No. 1321/TF2)
USE No. 1321CN IN CANADA
TO 110VAC
UNSWITCHED
OUTLET (24HR)
+
CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE
ALARM HEADQUARTERS OR A CENTRAL STATION
SHALL BE PERMITTED ONLY WITH THE PERMISSION
OF THE LOCAL AUTHORITY HAVING JURISDICTION.
THE BURGLAR ALARM SIGNAL SHALL NOT BE CON-
NECTED TO A POLICE EMERGENCY NUMBER.
ALARM OUTPUT
10.5-13.8VDC, 2A MAX.
(600mA MAX FOR UL USAGE,
INCLUDING AUX. POWER)
STEADY FOR BURGLARY/PANIC,
PULSING FOR FIRE (e.g. USE ADEMCO
No. 702 OR 719 SIREN, OR 12V BELL)
FUSE
FOR REPLACEMENT,
USE SAME VALUE
3A
BLK
RED
GRN
YEL
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 5
ZONE 6
HI
LO
HI
LO
TIP
(BROWN)
RING
(GRAY)
TIP
(GREEN)
RING
(RED)
INCOMING
PHONE LINE
LOCATED AT
LOWER RIGHT OF
CIRCUIT BOARD
HANDSET
BLACK
RED
+
No. 4110XM
SUMMAR
Y OF CONNECTIONS
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 1
ZONE 2
HI
LO
HI
LO
1000
OHMS
EOLR
1000
OHMS
EOLR
ZONE 3
ZONE 4
HI
LO
HI
LO
MAXIMUM LOOP RESISTANCE (EACH ZONE) 300 OHMS (PLUS EOLR)
RESPONSE, ZONES 1-6:300-500MSEC
ZONE 3 CAN BE PROGRAMMED FOR N.C. SENSOR FAST RESPONSE TO
AN OPEN: 10MSEC MAX
ZONE 5 CAN BE PROGRAMMED FOR USE AS A FIRE ZONE. SEE DIAGRAM
No. 4116
ARMING/DISARMING
KEYSWITCH
(SINGLE LED, LOCKSWITCH, TAMPER)
BATTERY
(e.g. No. 90-12)
CHARGING
VOLTAGE
13.8VDC
NOTE:
MULTIPLE KEYPADS MAY BE USED.
A MAX. OF 220 FT. OF #22 WIRE OR
550 FT. OF #18 WIRE MAY BE USED.
WARNING:
TO PREVENT RISK OF SHOCK,
DISCONNECT TELEPHONE LINE
AT TELCO JACK BEFORE
SERVICING THIS UNIT.
THIS EQUIPMENT SHOULD BE INSTALLED IN
ACCORDANCE WITH THE NATIONAL FIRE PRO-
TECTION ASSOCIATION'S STANDARD 74 (NATION-
AL FIRE PROTECTION ASSOC., BATTERYMARCH
PARK, QUINCY, MA 02269). PRINTED INFORMA-
TION DESCRIBING PROPER INSTALLATION, OPER-
ATION, TESTING, MAINTAINANCE, EVACUATION
PLANNING AND REPAIR SERVICE IS TO BE PRO-
VIDED WITH THIS EQUIPMENT.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT
CAUSE HARMFUL INTERFERENCE, (2) IT MUST ACCEPT ANY INTER-
FERENCE THAT MAY CAUSE UNDESIRED OPERATION.
TO
AUX PWR
TERMS
+
-
+
-
EOL
POWER
SUPER-
VISION
RELAY
MODULE
ELOR-1
5
4
4-WIRE SMOKE
OR COMBUSTION
DETECTOR
1000
EOLR
HEAT
DETECTOR
TO ZONE 5
*
+
RED
BLK
VIOLET
*
IF PROGRAMMED FOR FIRE
14 15
DOC LOAD NO.:3
GEL. LEAD ACID TYPE.
BATTERY NORMALLY NEED NOT BE
R
EPLACED FOR AT LEAST 3 YRS.
BATTERY CAPACITY FOR EMERGENCY
ST
ANDBY USE AT LEAST 4 HOURS.
4110XM-SOC-V2
REMOTE
K
EYPAD
(e.g. 6150)
91 2 3 7 125