Data Fields
Field Function Programmed Value [ ] = Default Value
SYSTEM OPTIONS (*20-*28)
*20 MASTER SECURITY CODE [4] [1] [1] [0]
Enter 4 digits, 0-9 (entry of all 4 is mandatory).
Use of a "9" in the last position inhibits the Ambush feature.
*21 QUICK ARM ENABLE
[0],
0 = no; 1 = yes. If enabled, [#] key can be used instead of security code
when arming the system.
*22 KEYSWITCH ENABLE
[0]
0 = no; 1 = yes
*23 FORCE BYPASS FUNCTION
[0]
0 = no; 1 = yes. Allows all faulted zones to be bypassed by entering
[Security Code] + [Bypass]. Zones that are bypassed by this function will
be displayed after the bypass is initiated.
*24 NOT USED (Must be set to “00”) [0] [0]
*27 AUDIBLE EXIT WARNING [1]
0 = no; 1 = yes. If selected, beeping occurs during exit time and changes
from slow to rapid beeping during last 5 seconds of exit delay.
*28 CONFIRMATION OF ARMING DING [0]
0 = no; 1 = yes. If selected, external sounder will sound for approximately
1 second at end of exit time or at time of kissoff of closing report, if
programmed.
*29 FIRE SOUNDER TIMEOUT
[0]
0 = sounder timeout, 1 = no sounder timeout. Enter 0 if sounder timeout
for fire zones is desired (uses time programmed in field *30).
*30 ALARM SOUNDER TIMEOUT
[1]
Enter time for external sounder to shut off after alarm occurs.
0 = no timeout; 1 = 4 min; 2 = 8 min; 3 = 12 min
PROGRAMMING HARDWIRE ZONES (*31-*37)
*31 ZONE 1 RESPONSE TYPE [1]
*32 ZONE 2 RESPONSE TYPE [4]
*33 ZONE 3 RESPONSE TYPE [3]
*34 ZONE 4 RESPONSE TYPE [3]
*35 ZONE 5 RESPONSE TYPE [9]
*36 ZONE 6 RESPONSE TYPE [7]
ZONE TYPES FOR PROGRAMMING FIELDS *31-37
0 = DISABLED (or Undefined) 6 = 24 HR (Silent)
1 = ENTRY/EXIT, Burglary 7 = 24 HR (Audible)
2 = Not used 8 = 24 HR (Auxiliary)
3 = PERIMETER, Burglary 9 = FIRE (Fields *35 and *37
4 = INTERIOR/FOLLOWER, only) enter # + 10
5 = TROUBLE BY DAY/ALARM 10 = INTERIOR W/DELAY,
BY NIGHT, Burglary Burglary (To program,
Enter # + 10)
*37 ZONE 7 RESPONSE TYPE
[6]
Console Panic: Key B or 6 & #. Only zone types 0, 6, 7, 8, 9 apply.
Entry of a number other than one specified will give unpredictable results.