Figure 2.2 Enclosure Base Layout.
Spares Pack
The Accord control panel comes with a spares pack. This contains ten zone links, five
mounting pillars and the battery connector leads.
Mains Supply Fuse
Mains Entry Point
Mains Cable Clamp
Cable Entry Holes Keyhole Mounting Switch
User Instructions
Mounting Holes
User Instructions Retaining Clip
90 mm
195 mm
23
Night Set [3]
To Night Set the system:
Enter your User Code then press the 3 (Night Set) key.
This starts the setting of the system using the Night Set zone programming.
This allows a sub-set of the system to be set.
The Day LED will flash during the Exit Time.
To cancel the setting procedure press the Ö (Escape) key.
Once the system sets two confirmation beeps are emitted by the keypad and
internal speaker; after this the Ö (Escape) key does not function.
 The activation of the keypad buzzer and internal speaker are dependant on the
programming of Programming Group 4  Option 4 Part Set Exit Warning.
Easy Set  allows users to Night Set the system without entering their User Code. If
Easy Set is programmed you may set the system by pressing the # key, then the 3
(Night Set) key. See SECTION 3: Programming the Accord; Group 4  Option 8
Easy Set
.
Unsetting
To Unset the system the user should go to the keypad via the agreed entry route and
enter their User Code.
Unsetting After or During an Alarm
On the keypad the LED corresponding to the first zone to go into alarm illuminates.
Entering a User Code stops any alarm that is in progress. To reset the system enter the
User Code again.
Note: If Engineer Reset for Alarms is enabled only the Engineer Code can reset the
system after an alarm condition. See Section 3: Programming the Accord;
Group 5  Option 3 Engineer Reset for Alarms
.
Engineer Setting and Unsetting
The Engineer Code can be used to set the system (Full, Part or Night). It can only be
used to unset the system when it was previously used to set it.
Testing the System [5]
To Test the zones and outputs on the system enter your code then press the 5 (Test)
key.
The Bell output, LEDs 1  8 and the Tamper LED on the keypad, will activate for five
seconds. The Strobe output flashes until the test is finished.
Once the keypad LEDs have deactivated test each zone in turn, activate the zone and
verify that the corresponding LED on the keypad illuminates and you hear two beeps
from the keypad.
To exit test mode enter your code, the keypad beeps twice to confirm.