CONTACT ID REPORTING
This is the only format that can identify all 64
protection zones by their unique zone (Contact) ID
numbers, and provides a l-digit event qualifier and
3-digit,
specifically defined event code.which
quickly identifies the condition being reported.’
Contact ID reports in DTMF (Dual Tone Multi-
Frequency @ 10 characters per second) and
responds to a 1400 Hz followed by 2300 Hz
handshake, and a 1400 Hz kissoff. This format also
uses checksum instead of two message verification.
A complete report takes under 3 seconds.
ADVISORY
Ademco’s new Contact ID reporting IS
capable of uniquely reporting eH 64
zones
of Information, as
well
as
openlngs and
closings for all 22 users, to central
stations equipped with the Ademco 685
receiver
using
software level 4.4 or
higher. 685 software levels below 4.4
cannot support Contact ID reportlng. For
lnformatlon regardlng updatlng the 685
receiver, contact Ademco’s Technlcal
Support group at l-800-645-7492.
VII., PROGRAMMING THE SYSTEM
The system is shipped with a set of pre-
programmed values that are. designed to meet the
needs of many installations. These can be changed
by the installer to suit specific needs if desired. In
addition, four
sets of
pre-programmed
communication default values can also be loaded by
the installer, each set designeo for a specific
communication format. These too can be changed to
suit the needs of a particular installation.
There ‘are five sets of pre-programmed defaults
Changes to these pre-programmed values can be
programmed directly from the keypad or from a
computer terminal using the 413OPC Downloading
software, an IBM compatible computer and a HAYES
1200 SMARTMODEM. The following paragraphs
describes how to load the various default
programming sets.
For instructions on making
changes to particular programming fields, or for
using downloading, refer to the
Technical Reference
Manual.
For alpha
Controls, English Language descriptions of
the zones and a custom installer message (which
appears when the system is ready to arm) can be
programmed.
Refer to the instructions in the
Technical Refenmce Manual
for details.
The programming fields are grouped into two sets
of addresses. The first set is accessed as soon as
programming mode is entered. To access the
second set of addresses (indicated on the
programming form by a -1. in front of the 2-digit
field address), press ‘94 while in programming
mode.
To return to the first set of addresses,
press l 99.
To program specific data fields, press I’] plus the
2digit field address, then make the required entry.
The console will beep when a field has been
completely programmed and will automatically
display the next data field in numerical order.
To view .the contents of a data field, press [#] plus
the 2-digit field address. The field’s entries will be
displayed, but no changes to these entries can be
made.
available (one standard, plus four different
tiotimunication defaults). Any one of these can be
loaded into the system’s memory by doing the
following:
1. Enter programming mode by pressing [‘I and
[#] at the same time and within 30 seconds
after power is applied. OR Enter the installer
code, and press CODE + [O] +[O].
2. Load one of the default programming sets by
entering one of the following code sequences:
Loads standard defualt values.
Standard Low Speed 3+1/4+!
‘94’82 Ademco High Spee&
‘94’83
Expanded 4+2
A complete list of the default values can be found in
the Technical Reference Manual.
To Exit programming mode, press either l 98 or
l 99. Use
‘98 to prevent re-access to
programming mode by installer code method. ‘99
allows installer code access to programming mode.