PARTITION-SPECIFIC FIELDS
(Duplicate this page for each partition in the installation.)
To program these fields,
1. Press *91 to select a partition.
2. Enter a partition-specific field number (ex. *09).
3. Repeat steps 1 & 2 for each partition in the system.
4. To return to the global program fields, press *99.
PARTITION #____ PROGRAM FIELDS
1st Page Fields
*09 ENTRY DELAY #1 |
[02] (00-15 times 15
seconds)
*10 EXIT DELAY #1 | [03] (00-15 times 15
seconds)
*11 ENTRY DELAY #2 | [06] (00-15 times 15
seconds)
*12 EXIT DELAY #2 | [08] (00-15 times 15
seconds)
*13 ALARM SOUNDER DURATION |
01-15 times 2 minutes [04]. Minimum 4 minutes for UL.
*16 CONFIRMATION OF ARMING DING
1=enable; [0=disable]
*22 CONSOLE PANIC ENABLES
1=enable; 0=disable [0-0-1] 95 96 99
*23 MULTIPLE ALARMS
[1=yes]; 0=no
*29 QUICK ARM
[1=yes]; 0=no
*32 PRIMARY SUBSCRIBER ACCT #
|
| | |
Enter 00-09; B-F (11-15) [15 15 15 15]
*38 INHIBIT BYPASS OF A ZONE |
01-64; [00 if all zones (except Fire zones) can be bypassed]
*39 ENABLE OPEN/CLOSE REPORT
FOR INSTALLER CODE 1=enable; [0=disable]
*84 SWINGER SUPPRESSION |
01-15 alarms [15]; Must be "00" (disabled) for UL.
*85 ENABLE DIALER REPORTS
FOR PANICS & DURESS 95 96 99 Duress
1=enable; [0=disable]
*87 ENTRY WARNING
[1=continuous]; 0=3 beeps
*88 BURG. ALARM COMM. DELAY |
1=16 seconds; [0=no delay]
*90 SECONDARY SUBSCRIBER ACCT #
|
| | |
Enter 00-09; B-F (11-15) [15 15 15 15]
2nd Page Fields
1*43 ENABLE PERM. LCD DISPLAY BACKLIGHT
1=enable; [0=disable] When disabled, display lights when any
key is pressed, and turns off after period of keypad inactivity.
1*45 ENABLE CONSOLE
ANNUN. DURING EXIT DELAY
1=enable; [0=disable] Produces quick beeping during exit delay
if enabled.
1*47 ENABLE CHIME ANNUN.
ON EXTERNAL ALARM SOUNDER
1=enable; [0=disable]
1*52 CANCEL REPORT RESTRICTION
1=no restriction; [0=within Bell Timeout period only]
1*76 ACCESS CONTROL RELAY FOR PARTITION |
Relay will be pulsed for 2 seconds whenever code + [0] is
pressed. Enter 00-16 [00]=none
3rd Page Fields
2*05 AUTO-ARM DELAY
Enter the time between the end of the arming window and the start
of auto-arming, in values of 1-14 times 4 minutes 00=instant;
[15=no auto arm at all]. When this delay expires, the Auto-Arm
Warrning Period begins.
2*06 AUTO-ARM WARNING PERIOD
This is the time during which the user is warned to exit the
premises prior to the auto-arming of the system (beeps every 15
seconds; "ALERT" displayed). Enter 01-15 minutes. 00=instant at
end of arming delay .
2*07 AUTO-DISARM DELAY
This is the time between the end of the disarming window and the
start of auto-disarming. Enter 01-14 times 4 minutes; 00=instant at
end of window; 15=no auto-disarm.
2*08 ENABLE FORCE ARM FOR AUTO-ARM
2*09 OPEN/CLOSE REPORTS BY EXCEPTION
1=enable; [0=disable]; If enabled, only openings and closings
occurring outside the scheduled opening/closing windows will
trigger dialer reports. Opening reports will also be suppressed
during the closing window, in order to prevent false reports when
the user arms the system and then reenters the premises to
retrieve a forgotten item.
2*10 ALLOW DISARMING ONLY DURING
ARMING/DISARMING WINDOWS
See system-wide field 2*11 if enabling field 2*10. This feature
adds high security to the installetion.
2*18 ENABLE GOTO FOR THIS PARTITION
1=enable; [0=disable]
2*20 ENABLE J7 TRIGGERS by PARTITION
0=disable for displayed partition; [1=enable for displayed
partition]