3rd Page Programming Fields
(press *94) PARTITIONING SETUP FIELDS
Refer to the PARTITION-SPECIFIC program fields for
programming each partition’s variable characteristics.
1*71 12/24 HOUR TIME STAMP FORMAT
[0=12 hour]; 1=24 hour
1*72 EVENT LOG PRINTER ON-LINE
[0=disable]; 1=enable
1*73 PRINTER BAUD RATE 1=300; [0=1200]
1*74 RELAY TIMEOUT XX MINUTES | |
Enter the relay timeout, 0-127 in multiples of 2 minutes, desired for
#80 Menu Mode time driven event relay command numbers "04/09"
and #93 Menu Mode Relay Programming output command "56".
1*75 RELAY TIMEOUT YY SECONDS | |
Enter the relay timeout, 0-127 seconds, desired for #80 Menu Mode
time driven event relay command numbers "05/10" and #93 Menu
Mode Relay Programming command "57".
1*76 ACCESS CONTROL FOR PARTITIONS
2*00 NUMBER OF PARTITIONS
Enter 1-8 [1]
2*01 DAYLIGHT SAVINGS TIME | |
START/END MONTH Start End
00-12; if no daylight savings time, enter 00,00; default=04,10]
2*02 DAYLIGHT SAVINGS TIME |
START/END WEEKEND # Start | End
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to
last; 7=3rd from last [1,5; 1st Sunday in April, last in Oct.]
2*05 AUTO-ARM DELAY |
2*06 AUTO-ARM WARNING PERIOD |
2*07 AUTO-DISARM DELAY |
2*08 ENABLE FORCE ARM FOR AUTO-ARM
2*09 ENABLE OPEN/CLOSE REPORTS
BY EXCEPTION
2*10 ALLOW DISARMING ONLY DURING
ARMING/DISARMING WINDOWS
2*11 ALLOW DISARM OUTSIDE WINDOW
IF ALARM OCCURS
Used only if field 2*10 (partition-specific field) is set to "1". If this
field is enabled ("1") the system can be disarmed outside the
disarm window if an alarm has occurred. If "0", disarming can only
be done during the disarm window. If field 2*10 is set to "0" for a
partition, this field has no effect for that partition.
SCHEDULING RELATED DIALER REPORTS
2*13 2*14
1st Digit 2nd Digit
|
| Early opening report code
|
| Early closing report code
|
| Late opening report code
|
| Late closing report code
|
| No opening (late to open) report code
|
| No closing (late to close) report code
|
| Auto-arm failure report code
|
| Access schedule changed report code
2*17 NUMBER OF CODES PER PARTITION
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
Enter 01-99. Total must be less than or equal to 128.
[Default=99 in part. 1; 01 in all other partitions]
2*18 ENABLE GOTO FOR THIS PARTITION
2*19 USE PARTITION DESCRIPTORS
[0=disable]; 1=enable
2*20 ENABLE J7 TRIGGERS BY PARTITION
2*21 ENABLE SUPERVISION PULSES FOR LRR
TRIGGER OUTPUTS | |
Used for supervised connection to 7920SE. F B S
Enter 0 to disable or 1 to enable the listed outputs.
F= Fire; B= Burglary; S= Silent panic/duress