– 10 – About The Keypads General IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during y
– 11 – Functions Of The Keypad 1OFF4MAX7INSTANTREADY2AWAY5TEST8CODE03STAY6BYPASS9CHIME#SUPERTROUBLEARMEDREADY6160CR-003-V1SPEAKERLCDDISPLAYLEDSFUNCT
– 12 – Functions Of The Keypad (cont’d)ALPHA DISPLAY WINDOW: A 2-line, 32-character Liquid Crystal Display (LCD). Displays protection point identif
–13 – Functions Of The Keypad (cont’d) ✳ READY : When depressed prior to arming the system, the keypad will display all open protection zones wi
– 14 – Entry/Exit Delays General Information Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm
–15 – Security Codes & Authority Levels General Information At the time of installation, you were assigned an authority level and a personal fou
– 16 – Security Codes & Authority Levels (cont’d) Authority Levels Authority levels define the system functions a particular user can perform. D
–17 – Security Codes & Authority Levels (cont’d) General Rules on Authority Levels and Changes • A user may not delete or change the user code
– 18 – Security Codes & Authority Levels (cont’d) To Add a User IMPORTANT: Temporary users should not be shown how to use any system function th
–19 – Security Codes & Authority Levels (cont’d) MULTI-ACCESS ? 0 = NO , 1 = YES If you as a user have access to other partitions, the keypad wi
– 2 –
– 20 – Security Codes & Authority Levels (cont’d) To Change a User’s Code CODE 1. Enter Master or Manager code and press the 8 key +
–21 – Accessing Other Partitions To Access Another Partition Each keypad is assigned a default partition for display purposes, and will show only th
– 22 – Accessing Other Partitions (cont’d) Global Arming Notes: • When performing a Global Arm, if there are faults in any of the selected partitio
–23 – Accessing Other Partitions (cont’d) The following is an example of what would be displayed for a fault condition on Zone 002 (Loading Dock Win
– 24 – Accessing Other Partitions (cont’d) Common Lobby Operation When an installation consists of a partition that is shared by users of other part
–25 – Accessing Other Partitions (cont’d) How User Codes Affect the Common Lobby Codes with “Global” Arming If your code is given global arming when
– 26 – Checking For Open Zones Using the ✴ READY Key Before arming your system, all protected doors, windows and other protection zones must be c
–27 – Displaying All Zone Descriptors Using the ✳ READY Key The Alpha Keypads can also display all the zone descriptors that are programmed in yo
– 28 – Bypassing Protection Zones Using the 6 BYPASS Key This key is used when you want to arm your system with one or more zones intentionally
–29 – Bypassing Protection Zones (cont’d) Quick Bypass Your system allows you to easily bypass all open (faulted) zones without having to enter zone
– 3 – TABLE OF CONTENTS SYSTEM OVERVIEW ...5 General ...5 A Partitioned
– 30 – Arming Perimeter Only (With Entry Delay ON) Using the 3 STAY key Use this key when you are staying home, but might expect someone to use
–31 – Arming Perimeter Only (With Entry Delay OFF) Using the 7 INSTANT Key Use this key when you are staying home and do not expect anyone to us
– 32 – Arming All Protection (With Entry Delay ON) Using the 2 AWAY Key Use this key when no one will be staying on the premises. When armed in
–33 – Arming All Protection (With Entry Delay OFF) Using the 4 MAXIMUM Key Use this key when the premises will be vacant for extended periods of
– 34 – Disarming And Silencing Alarms Using the 1 OFF Key The OFF key is used to disarm the system and to silence alarm and trouble sounds. See
–35 – Using The Keyswitch General Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light
– 36 – Chime Mode Using the 9 Key Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mod
–37 – Viewing Alarm Company Messages General Information Users of the system may periodically receive messages on their display screens from their m
– 38 – Panic Keys (For Manually Activating Silent And/Or Audible Alarms) Using Panic Keys Your system may have been programmed to use special key co
– 39 – Speed Key (Macros) General Information The “A”, “B”, “C”, and/or “D” keys can be used to activate a string of commands up to 32 keystrokes
– 4 – PANIC KEYS... 38 Using Panic Keys ...38 SPEED KEY (MACROS)...
– 40 – Speed Key (Macros) (cont’d) Executing To execute a Speed Key sequence, do the following: If a lettered key, A-B-C, has been assigned as a Spe
– 41 – Access Door Control General Information Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momenta
– 42 – Using #70 Relay Menu Mode General Information Your system may be set up so that certain lights or other devices can be turned on or off by us
– 43 – Using Schedules Delaying the Closing Time Your system’s programmed schedules may automatically arm the system at a predetermined time. In the
– 44 – Using Schedules (cont’d) Programming Temporary Schedules Temporary schedules only affect the partition from which it is entered. Temporary sc
– 45 – Using Schedules (cont’d) DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the te
– 46 – Programming Device Timers General Information Device timers consist of an ON time & an OFF time, and selected days of the week in which t
– 47 – Programming Device Timers (cont’d) 00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the d
– 48 – Using #77 Instant Activation Mode The #77 Instant Activation Mode is used to activate outputs, bypass zones, etc. immediately upon exiting th
– 49 – Using #77 Instant Activation Mode (cont’d) Bypass Commands Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices for
– 5 – System Overview General Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategicall
– 50 – Using #77 Instant Activation Mode (cont’d) Additional Commands Action Code Action Specifier 77 Access Point Group Enable Group # 78 Access
– 51 – Event Log Procedures General Information The system has the ability to record various events in a history log wherein each event is recorded
– 52 – Event Logging Procedures (continued) 4. Use the [3] & [1] keys (for next and previous categories respectively) to display the categories
– 53 – Testing The System (To Be Conducted Weekly) Using the 5 TEST Key The TEST key puts your system into Test mode, which allows each protecti
– 54 – Fire Alarm System Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency,
– 55 – Fire Alarm System (cont’d) Fire Display Lock If several zones produce an alarm before any are silenced, the system can be programmed to lock
– 56 – Trouble Conditions Typical Trouble Displays The word CHECK or TRBL on the Keypad’s display, accompanied by a rapid "beeping" at the
– 57 – Trouble Conditions (cont’d) • A display of "COMM. FAILURE" at the Keypad indicates that a failure has occurred in the telephone co
– 58 – Emergency Evacuation Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the Natio
– 59 – Maintaining Your System Taking Care of Your System The components of your security system are designed to be as free of maintenance as possib
– 6 – System Overview (cont’d) A Partitioned System Simply stated, a partitioned system shares one physical alarm system among different users, each
– 60 – Maintaining Your System (cont’d) Silencing Low Battery Warning Tones at the Keypad The keypad’s warning tones can be silenced by performing a
– 61 – Quick Guide To System Functions FUNCTION PROCEDURE COMMENTS Check Zones Press [✱]. To view faulted zones when is system not ready Display
– 62 – Quick Guide To System Functions (cont’d) FUNCTION PROCEDURE COMMENTS Delete a User Enter master/manager code. Press CODE [8]. Enter user n
– 63 – Summary Of Audible Notification (Alpha Display Keypads) SOUND CAUSE DISPLAY LOUD, INTERRUPTED* Keypad & External FIRE ALARM FIRE is d
– 64 – UL NOTICE: This is a “GRADE A” system. “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT” This equipment has been tested to FCC req
– 65 – “FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this e
– 66 – CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment
– 67 – WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM While this system is an advanced design security system, it does not offer guaranteed protect
– 68 – Index #70 command ... 42 4285 or 4286 VIP module ... 9, 42 AC Loss ...
– 69 – Memory of Alarm...7, 34 Messages...37 Modem Comm...
– 7 – System Overview (cont’d) Burglary Protection The burglary protection portion of your system must be turned on or "armed" before it w
– 70 – LIMITED WARRANTY Honeywell International Inc., 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in conformance with it
– 71 –
¬.9'lK3522V2 6/04 Rev A 165 Eileen Way, Syosset, New York 11791Copyright © 2004 Honeywell International, Inc.www.honeywel
– 8 – System Overview (cont’d) Speed Key (Macros) The system can store a string of up to 32 keystrokes, which can be activated anytime by simply pre
– 9 – System Overview (cont’d) Master Keypad Operation A "Master" keypad is one on which the status of all 8 partitions is displayed simul