ADEMCO VISTA-20HWse Technical Information

Stöbern Sie online oder laden Sie Technical Information nach Sicherheitszugriffskontrollsysteme ADEMCO VISTA-20HWse herunter. ADEMCO VISTA-20HWse System information Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 9
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Ademco Vista-20SE/Vista-20HWSE
General
This system offers you three forms of protection: burglary, fire and emergency. Your system consists of at least one
keypad that provides control of system operation, and includes various sensors that provide perimeter and interior
burglary protection, plus smoke or combustion detectors designed to provide early warning in case of fire.
Zones
Your system’s sensing devices have been assigned to various “zones.” For example, the sensing device on your Entry/Exit
door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on.
These number will appear on the display, along with a description for that zone (if programmed), when an alarm or
trouble condition occurs.
Burglary Protection
Your system provides four modes of burglary protection: stay, away, instant and maximum, and allows you to bypass
selected zones while leaving the rest of the system armed. You must turn on or “arm” the burglary protection portion of
your system before it will sense burglar alarms. The system also provides a chime mode, for alerting users to the
opening of protected doors and windows while the system is disarmed. Refer to the other sections of this manual for
procedures for using these features.
The following table lists the four different arming modes and the results of each:
Seitenansicht 0
1 2 3 4 5 6 7 8 9

Inhaltsverzeichnis

Seite 1

Ademco Vista-20SE/Vista-20HWSE General This system offers you three forms of protection: burglary, fire and emergency. Your system consists of at l

Seite 2 - Arm & Disarm the System

Arming Mode Exit Delay Entry Delay Perimeter Armed Interior Armed Away Yes Yes Yes Yes Stay Yes Yes Yes No Instant Yes No Yes No Maximum Yes No Yes Ye

Seite 3 - Panic Alarms

Quick Bypass: 1. Enter security code then press bypass. Example: [7] [2] [9] [6] then press the BYPASS key. 2. In a few moments, all open zones will

Seite 4 - Trouble Conditions

A fire alarm sends a fire alarm message to the alarm monitoring company* and uniquely activates keypad and any external sounders (FIRE plus a zone num

Seite 5 - User Access Codes

Telco Fault (or CHECK and zone 94) If the telephone line monitor feature has been programmed for your system, this display indicates that the telephon

Seite 6

To Activate Devices Enter security code then press [#] + [7] + then enter the number representing the device you wish to activate. To Deactivate Devic

Seite 7 - System Testing

To Delete a User: 1. Enter master code then press CODE key. 2. Enter the two-digit User Number (03-16) for the user whose code you are deleting. 3.

Seite 8 - Other System Information

2. Enter the security code then press test key. 3. Listen. The external sounder should sound for 2 seconds and then turn off. If the sounder does no

Seite 9

In addition, a battery-operated smoke detector with a low battery also emits a single "chirp" sound approximately once every 20–30 seconds,

Kommentare zu diesen Handbüchern