ADEMCO Vista-128FB Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Sicherheitszugriffskontrollsysteme ADEMCO Vista-128FB herunter. Vista 128FB - Info Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - 4XLFN6WDUW*XLGH

V128FB-PRV1 10/9899,,6677$$))%%&RPPHUFLDO)LUHDQG%XUJODU\3DUWLWLRQHG6HFXULW\6\VWHPZLWK6FKHGXOLQJ4XLFN6WDUW*XLGH*FIREFIREPULL®Previ

Seite 2

– 10 –1*42CALL WAITING DEFEAT [0] 1=Yes; 0=No.1*43PERM. KEYPAD BACKLIGHT [0] 1=enable; 0=disable When disabled, display lights whenany ke

Seite 3 - Table Of Contents

– 11 –2*11ALLOW DISARM OUTSIDE WINDOW [0] IF ALARM OCCURSUsed only if field 2*10 (partition-specific field) is set to "1". Ifthis fie

Seite 4

– 12 –SUMMARY OF PROGRAMMING COMMANDS• To enter program mode, enter installer code + [8] + [0] +[0] + [0]• To set standard defaults, press *97• To se

Seite 5

– 13 –Partition-Specific Fields(Duplicate this page for each partition in the installation.)To program these fields,1. Press *91 to select a partitio

Seite 6 - Program Field Categories

– 14 –3rd Page Fields2*05AUTO-ARM DELAY [15] | Enter the time between the end of the arming window andthe start of auto-arming warning period,

Seite 7

– 15 –Programming With #93 Menu Mode#93 Main Menu OptionsThe following field should be programmed before beginning: 2*00: Number of Partitions.ULFor

Seite 8

– 16 –DEVICE PROG?0=No 1=YesFor defining the following device characteristics for addressabledevices, including keypads, RF receivers (5881

Seite 9 - 12345678 910

– 17 –PROGRAM TOOL?0 = NO, 1 = YES 0If a program tool is being used, enter 1. If not using a tool,enter 0. When a 0 is entered, the system will

Seite 10

– 18 –↓ Zone Number010 ZONE RESPONSEPerimeter 03Zone Type 03 entry shownEach zone must be assigned a zone type, which defines the wayin which the sys

Seite 11

– 19 –010 INPUT TYPERF Xmitter 3Note that input types 4 & 5are valid for certain 5800Series transmitters only (e.g.,5801, 5802, 5802CP &

Seite 12

–2–

Seite 13 - 995 996 999 Duress

– 20 –5800 Series RF Transmitter Loop Designations010 LEARN S/N?1 = YES, 0 = NO 1If the device’s serial number has not been previously “enrolled,”y

Seite 14 - Must be "1" for UL

– 21 –010 INPUT S/N Axxx-xxxxThis prompt is displayed if 1 (YES) is entered in response tothe "LEARN S/N?" prompt. The serial number m

Seite 15 - #93 Main Menu Options

– 22 –Sequential Mode ProgrammingUsually, serial numbers are enrolled during Zone Programming. If not, use #93 Menu Mode to enroll serialnumbers (fo

Seite 16 - Zone Programming

– 23 –ENTER ZN NO.(000 = QUIT) 010Zone Number Entered ↑ Enter the first zone number to be enrolled (e.g., zone 010).Press [∗] to continue.The syst

Seite 17

– 24 –010 CONFIRMED SL:1 A022-4064 When the system sees activity on the appropriate input, it will beepthree times and display the confirmation

Seite 18

– 25 –The programming sequence that follows assumes that you will be entering all reports for the system at onetime. In actuality, you may skip from

Seite 19

– 26 –TROUBLE RESTOREGRP 001-016 000Enter the first digit of the trouble restore code (single-digitentry) and press [∗]. The second digit wil

Seite 20 - 1 = YES, 0 = NO 1

– 27 –System Group 2 CodesSYSTEM GROUP #2 ?1 = YES 0 = NO 0To enter System Group #2 codes, press 1 (Y).STAY1st 00 2nd 00Enter the first

Seite 21

– 28 –System Group 4 CodesSYSTEM GROUP #4 ?1 = YES 0 = NO 0To enter System Group #3 codes, press 1 (Y).WALK TEST START1st 00 2nd 00Enter

Seite 22 - Sequential Mode Programming

– 29 – PART DESCRIP? for creating 4-character partition names. EXIT EDIT MODE? Press 1 to exit back to #93 Menu Mode.4. Refer to the sections tha

Seite 23 - Zone Number Entered

–3–Table Of ContentsRECOMMENDED PROGRAMMING PROCEDURE ...

Seite 24 - Report Code Programming

– 30 –6. Store the descriptor.When all desired words have been entered, press 8 to store the description inmemory.To review the zone descriptors, ke

Seite 25

– 31 –When using method 3b to enter alpha descriptors, each word will be found at the end ofthe group of words that begin with the same letter as it

Seite 26

– 32 –Alpha Descriptor Vocabulary(For Entering Alpha Descriptors. To select a word, press [#] followed by the word's 3-digit number.)NOTE: This

Seite 27

– 33 –*Notes: This factory-provided vocabulary of words is subject to change.Bulleted words in bold face type are those that are also available for us

Seite 28 - Alpha Descriptors Programming

– 34 –SOUND OPTIONIf device type 1 (alpha keypad) is entered, this prompt willappear. Keypads can be individually programmed to suppressarm/disarm be

Seite 29

– 35 –Long Range RadioIf device type 6 is chosen, the 6139 Keypad will function similar to the 7720PLRR Programming Tool. See Figure25-2 for the func

Seite 30

– 36 –The 6139 Keypad will display the following prompts, which are sent by the Long RangeRadio transmitter to the control.DEVICE ADDRESSEnter the dev

Seite 31

– 37 –Relay ProgrammingThe system supports up to 32 relay outputs. Relays can be used to perform many different functions andactions. Each relay mus

Seite 32 - (Word Space)

– 38 –If a specific "ZONE TYPE" is chosen, any zone of that response typegoing into alarm, trouble, or fault will cause the device to activa

Seite 33 - Device Programming

– 39 –02 A ZL ZT PSTP 0 0 00The keypad will display a summary STOP screen.Press [∗] to continue.02 RELAY ACTIONNO RESPONSEThe Relay

Seite 34 - SUPERVISED CF?

–4–Recommended Programming ProcedureThe following is a step-by-step procedure recommended for programming your VISTA-128FBsystem. 1. Set the keypads

Seite 35 - SPACE ENTER

– 40 –02 START: ACS PT(00-31) 00If the start zone type selected was 27 (access point), this promptwill be displayed. Enter the access po

Seite 36

– 41 –ECP ADDRESSFor relay modules (4204/4204CF), enter the actual relaymodule's address (01-15) as set by its DIP switches. Up to 8modules can

Seite 37 - Relay Programming

– 42 –XXX Assigned Zone000=QUIT 000Press [∗] to scroll through all zones in that list. Enter 000 +[∗]to quit.Press *99 to exit Program

Seite 38 - STT 0 0 0 00

– 43 –Relay Voice Descriptors and Custom Word Substitutes VocabularyWord IndexAir ...116Alarm...255And...

Seite 39

— 44 —Custom Word Substitutes for VIP Module AnnunciationA substitute word can be programmed for each of the 20 custom words used in your alpha zone d

Seite 40

— 45 —System Layout WorksheetsAs with any security system, you should first define the installation. This includes determining how manypartitions will

Seite 41

— 46 —SYSTEM DEFINITIONS BY PARTITION 9enter values or yes/no)Option Part. 1 Part. 2 Part. 3 Part. 4 Part. 5 Part. 6 Part. 7 Part. 8Entry Delay #1 (1

Seite 42 - Relay Voice Descriptors

— 47 —DEVICES (keypads, 4204, rf receivers, vip module, lrr, vgm)DeviceAddress TypeHomePartSoundOptSupvCF?KeypadGlobalDeviceAddress TypeHomePartSoundO

Seite 43

— 48 —ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 1-34-digit Access Partition 1 Partition 2 Partition 3SecurityCodeGroup0; 1-82-DigitUser #Glob

Seite 44 - RF Serial Number Clear Mode

— 49 —ZONE DEFINITIONS FOR ZONES 001-024ZoneNo.ZoneTypeParti-tion(1-8)InputType(1-8)Serial #DeviceLoopBell/RelayActivationReportCodeZone Information (

Seite 45 - System Layout Worksheets

–5–13. Exit Programming Mode.Exit programming mode by pressing either *98 or *99. Additional entries of *99 is required ifthe exit is being done from

Seite 46

— 50 —ZONE DEFINTIONS FOR ZONES 025-048ZoneNo.ZoneTypeParti-tion(1-8)InputType(1-8)Serial #DeviceLoopBell/RelayActivationReportCodeZone Information (p

Seite 47

— 51 —ZONE DEFINITIONS FOR ZONES 049-072ZoneNo.ZoneTypeParti-tion(1-8)InputType(1-8)Serial #DeviceLoopBell/RelayActivationReportCodeZone Information (

Seite 48

— 52 —ZONE DEFINTION FOR ZONES 073-096ZoneNo.ZoneTypeParti-tion(1-8)InputType(1-8)Serial #DeviceLoopBell/RelayActivationReportCodeZone Information (pa

Seite 49

— 53 —ZONE DEFINTION FOR ZONES 097-120ZoneNo.ZoneTypeParti-tion(1-8)InputType(1-8)Serial #DeviceLoopBell/RelayActivationReportCodeZone Information (pa

Seite 50

— 54 —ZONE DEFINTION FOR ZONES 121-128ZoneNo.ZoneTypeParti-tion(1-8)InputType(1-8)Serial #DeviceLoopBell/RelayActivationReportCodeZone Information (pa

Seite 51

— 55 —ZONE DEFINITIONS FOR RELAY SUPERVISORY ZONES 601-616ZoneNo.ZoneTypeReportCodeZone Information (part numbers)&Alpha Descriptor (3 words max.)

Seite 52

— 56 —ZONE DEFINITIONS FOR SUPERVISORY OF ECP DEVICE ZONES 800-831ZoneNo.ZoneTypeReportCodeZone Information (part numbers)&Alpha Descriptor (3 wor

Seite 53

— 57 —Output Relays WorksheetsApplicable only if Relays (4204/4204CF) are to be used.Output Devices – Programmed in the #93 Menu Mode in the Relay Pro

Seite 54

— 58 —OUTPUT RELAYS WORKSHEET (cont’d)STARTeither (EV) / (ZL) or (ZT) / (P) or bothSTOPeither (ZL) or (ZT)/(P) or bothOUTPUTDEV #(A) (EV) (ZL) (ZT) (P

Seite 55

— 59 —Choices for System Operation are:20 = Arming-Stay 37 = 2 Times Bell Time-out* 52 = Kissoff21=Arm Away 38 = Chime 54 = Fire Zone Reset22 = Disarm

Seite 56

–6–Program Field CategoriesIn the following pages, the programming fields have been arranged by category. Use this index to cross referencethe numeri

Seite 57

— 60 —Scheduling Menu PromptsTo program schedules, enter Scheduling program mode by pressing [Installer Code] + # + 80 to display thefirst choice of t

Seite 58

— 61 —Scheduling WorksheetsTime Windows Definitions Worksheet.The system provides 20 time windows that are defined with start and stop times. They ar

Seite 59 - (enter YY in field 1*75)

— 62 —Holiday Schedule Worksheet:The system provides up to 16 holidays that can be assigned for the system. Each holiday can be assigned toany combina

Seite 60 - Scheduling Menu Prompts

— 63 —Below is a list of the "Action" codes (desired actions) used when programming time driven events. Note thatthese codes are independent

Seite 61 - Scheduling Worksheets

— 64 —Limitation of Access WorksheetThe system provides up to 8 Access Schedules that can be programmed for the system. Fill in the requireddata on t

Seite 62

— 65 —Partition/Windows Mon Tue Wed Thu Fri Sat Sun5Disarm WindowStart Time HH:MMStop Time HH:MMArm WindowStart Time HH:MMStop Time HH:MM6Disarm Windo

Seite 63

— 66 —

Seite 64

— 67 —TRANSFORMERW/ENCLOSUREADEMCO No.1451(supplied)INPUT: 120VAC, 60HZ, 1.0A max. Connect to a dedicated circui

Seite 65

¬9)%359lV128FB-PRV1 10/98165 Eileen Way, Syosset, NY, 11791Copyright  1998 PITTWAY Corporation

Seite 66

– 7 –VISTA 128FB Programming FormSome fields are programmed for each partition (shown as shaded fields). If Programming a Multiple Partition System,

Seite 67 - SUMMARY OF CONNECTIONS

– 8 –*37DOWNLOAD COMMAND ENABLES 0 Dialer System Not Remote Remote Remote UploadDownloadShut

Seite 68 - ¬9)%359l

– 9 –*71PAGER PHONE # FOR OPENS/CLOSES Enter 0-9 f

Kommentare zu diesen Handbüchern

Keine Kommentare