Installation and Setup Guide
1-2
Compatible Devices
UL NOTE: For UL installations, use only UL Listed devices wherever compatible peripheral devices
are noted in these instructions.
Supports up to 8 Addressable Keypads: 6148/6150 Fixed-Word Display Keypads, 6164 Alpha
Keypad, 6128RF/6128RFH/6150RF/6160RF Keypad/Transceivers, 6160V Voice Keypad
Supports up to two (2)
Touch Screen (AUI) Devices (Symphony, 6270), which are in addition to the
standard eight (8) addressable keypads.
Supports up to five 4219, 4229 addressable basic wired zone expander modules
Supports 5881/5882EU/5882EUH/5883 series receiver and 5800/5800EU/5800H/5800AP series
transmitters
Outputs from up to 16 relays, two on-board triggers, and/or Powerline Carrier Devices (X-10 type)
-- Use any combination of 4204, 4229, 6164 relays and/or Powerline Carrier Devices.
-- Output functions (up to 48)
Alarm power output provides a 12VDC, 2 AMP (600mA max for UL) output that can drive
compatible sounders with a steady output for burglary/panic, or temporal pulse (3 pulses – pause –
3 pulses – pause – 3 pulses. . .) for fire. Uses current limiting circuitry for protection.
Auxiliary Power Output: 12VDC, 600 mA max. (500mA max. for UL); all outputs are power limited.
Backup Battery: Rechargeable (sealed lead-acid type) 12VDC, 4AH minimum (See Table on page 2-5,
Output Limitations to Meet CSFM 24-hour Battery Backup Requirements and UL Residential Fire
Installations)
Audio Alarm Verification (using AAV module, such as ADEMCO UVS); can be used in conjunction
with an output trigger to permit voice dialog between an operator at the central station and a
person at the premises.
Alternative Communication Media: Primary telephone number messages can be reported via ECP
connection to Ethernet TCP-IP Internet
AC Power Supply: Wired-in or Plug-in 110 (e.g 1321)/220VAC transformer (220VAC not for UL
installations)
Important Installation Highlights (Installer Please Read)
This system uses addressable keypads and Zone Expander Modules (see table of addresses in
Programming Overview section).
Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from
previous controls) and programmed in data fields *190-*196.
Zone Expander Modules must be set for specific addresses (07-11), based on the zone numbers used
(see table of addresses in 4219/4229 Expansion Zones section).
4204 Relay Modules must be set for specific addresses (12-15; see Connecting Relay Modules
section).
6164 Keypads must be set for two addresses: a keypad address and a zone expander address (if
using the keypad’s expansion zones).
This control will not power-up unless AC mains is connected (will not power-up on battery alone).
However, once the system is powered up, it will operate on battery power in case of AC mains loss.
Relays have two programming menu modes: Use *79 Menu mode to map module addresses and
device (output) numbers. Use *80 Menu mode to define the output functions (see Output Device
Programming section).
This system supports programmable function keys. Use *57 Menu mode to define the function keys
(see Function Key Programming section).
This system provides various paging features. Refer to the Programming Overview section for a
summary on pager programming.