ADEMCO VIA-30PSE PROGRAMMING FORM
FIELD FUNCTION PROGRAMMED VALUES [ ] = Default Value
–––––––– ––––––––––––––– –––––––––––––––––––––––––––––––––
SYSTEM SETUP (*20-*27)
*20 INSTALLER CODE
Enter 4 digits, 0-9...[4] [1] [1] [1]
*21 QUICK ARM ENABLE
[0 = no]; 1 = yes
*22 RF SYSTEM TYPE
[0 = none]; 1 = 5700 (4281); 2 = 5800 (5881)
*23 FORCED BYPASS FUNCTION
[0 = none]; 1 = bypass open zones
*24 RF HOUSE ID CODE [0][0]
MUST enter (01-31) for 5700 System. Enter also for 5827 Keypad
*25 WIRED EXPANSION/RELAY USED
[0 = none]; 1 = 4219; 2 = 4229; 3 = 4204
or 5827BD Keypad.
*26 VOICE MODULE ACCESS CODE
1st digit: Enter 1–9; 2nd digit: Enter only #+11 for '', #+12 for '#'.
[0] in either position = disabled.
*27 OUTPUT TO LONG RANGE RADIO
[0 = no]; 1 = yes. If yes selected, dialer reports to PRIMARY No. (field
*47) will also be sent via LRR. All dialer and LRR reports will be in Contact
ID format (overriding field *46 selection).
ZONE SOUNDS AND TIMING (*28-*39)
*28 SINGLE ALARM SOUNDING/ZONE
[0 = no]; 1 = yes
*29 FIRE SOUNDER TIMEOUT
[0 = fire sounder timeout]; 1 = no fire sounder timeout
*30 ALARM BELL TIMEOUT
0 = none; [1= 4 min]; 2 = 8 min; 3 = 12 min.; 4 = 16 min.
*38 ENTRY DELAY
0 = 0 sec ; 1= 20 sec; [2 = 30 sec]; 3 = 45 sec; 4 = 60 sec; 5 = 90 sec
EXIT Delay = ENTRY Delay + 15 sec
*39 AUDIBLE EXIT WARNING
0 = no; [1 = yes]
DIALER PROGRAMMING (*40-*50) In fields *40, *41, *42, enter up to the number of digits shown. Do not fill unused spaces.
Enter 0-9; #+11 for ''; #+12 for '#'; #+13 for a pause.
*40 PABX ACCESS CODE
Enter up to 4 digits.
If fewer than 4 digits entered, exit by pressing (and press 41, if entering next field). To clear entries from field, press 40 .
*41 PRIMARY PHONE No.
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing (and press 42, if entering next field). To clear entries from field, press 41 .
*42 SECONDARY PHONE No.
Enter up to 12 digits.
If fewer than 12 digits entered, exit by pressing (and press 43, if entering next field). To clear entries from field, press 42 .
*43 SUBSCRIBER ACCT No.
Enter 0-9; #+11 for B; #+12 for C; #+13 for D;
#+14 for E; [#+15 for F]. Enter as 4th digit, if 3+1 dialer reporting is to be used.
If only 3 digits used, exit by pressing (and press next field). To clear entries from field, press 43 .
Examples:
For Acct No. 1234, enter: 1234
For Acct No. B234, enter: #+11 2 3 4
For Acct No. 123, enter: 1 2 3
*45 PHONE SYSTEM SELECT
If Cent. Sta.
IS NOT
on a WATS line: [0 = Pulse Dial]; 1 = Tone Dial
If Cent. Sta.
IS
on
a WATS line: 2 = Pulse Dial ;3 = Tone Dial
*46 REPORT FORMAT
Also see field *27.
[0 = 3+1, 4+1 ADEMCO L/S STANDARD]
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 or undefined = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
*47 SPLIT/DUAL REPORTING [0 = Disable (Backup report only)]
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 =Alarms, Restore, Cancel Other Reports
2 =All Reports except Open/Close, Test Open/Close, Test
3 =Alarms, Restore, Cancel All Reports
4 =All Reports except Open/Close, Test All Reports
5 = All Reports (
Dual Reporting)
All Reports
**
A 10-digit code is sent to the pager consisting of
a 4-digit Subscriber #, a 3-digit Event code, & a
3-digit User or Zone #. See Installation
Instructions for an explanation of the 10-
digit code.
TO PRIMARY PHONE No. TO PAGING No.* (SECONDARY)
6 = All reports except Open/Close ** Alarms, Open/Close, Troubles
7 = All reports ** Alarms, Troubles
8 = All reports ** Alarms, Open/Close, Troubles
9 = All reports except Open/Close ** Alarms, Open/Close for Users 5 –
25, Troubles
* Can only be used if Primary reporting is Ademco Contact ID.
Entry of a number other than one specified will give unpredictable results.