Field Function Programmed Values [ ] = Table 1 Default Value
✱
43
PRIMARY SUBS ACCT #
See note on previous page
✱
44
SECONDARY SUBS ACCT #
See note on previous page
✱
47
PHONE SYSTEM SELECT
†
[1]
If Cent. Sta.
IS NOT
on a WATS line: 0 = Pulse Dial; 1 = Tone
Dial; if Cent. Sta.
IS
on
a WATS line: 2 = Pulse Dial ; 3 = Tone
✱
48
REPORT FORMATfor PRIM./SEC.
[7, 0]
Primary Secondary
0
= 3+1, 4+1 ADEMCO L/S STANDARD
1
= 3+1, 4+1 RADIONICS STANDARD
2
= 4+2 ADEMCO L/S STANDARD
3
= 4+2 RADIONICS STANDARD
6
or undefined
= 4+2 ADEMCO EXPRESS
7
= ADEMCO CONTACT ID REPORTING
8
= 3+1, 4+1 ADEMCO L/S EXPANDED
9
= 3+1, 4+1 RADIONICS EXPANDED
✱
49
SPLIT/DUAL REPORTING
[0]
0 = Disable (Backup report only)
TO PRIMARY PHONE No. TO SECONDARY PHONE No.
1 = Alarms, Restore, Cancel Others
2 = All except Open/Close, Test Open/Close, Test
3 = Alarms, Restore, Cancel All
4 = All except Open/Close, Test All
5 = All All
** Pager Message
TO PRIMARY PHONE No. TO PAGING
**
No. (Secondary)
A 7-digit code (plus optional 16-digit prefix) is 6 = All except Open/Close Alarms, Open/Close
‡
, Troubles
sent to the pager consisting of a 3-digit event code, 7 = All reports Alarms, Troubles
followed by 00 and a 2-digit user or zone number. 8 = All reports Alarms, Open/Close
‡
, Troubles
See Installation Instructions for an explanation of 9 = All except Open/Close Open/Close
‡
the pager code, which takes the following form:
‡
Will report users 0, 5-8 or
AAAAAAAAAAAAAAAA-EEE-00NN wireless arm/disarm button
Where: AAA…= optional 16 digits (see field *88) zones 26-33; all other zones
EEE = 3-digit event code: 911 (alarm), 101 (open), 102 (close), 811 (trouble) and users do not report
00 = always displayed
NN = 2-digit user number or zone number depending on type of event (EEE) that occurred
✱
50
15 SEC DIALER DELAY (BURG)
†
[0]
0 = no; 1 = yes; UL installations = 0
✱
51
PERIODIC TEST REPORT
†
[0]
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days (enter Test Code
in field
*
64)
✱
52
FIRST TEST REPORT OFFSET
† [2]
0 = 24 hour; 1 = 6 hours; 2 = 12 hours; 3 = 18 hours (Time to 1st
report from power up/programming or downloading).
✱
53
SESCOA/RADIONICS SELECT
[0]
0 = Radionics (0–9, B–F reporting); 1 = SESCOA (0–9 only
reporting). Select 0 for all other formats.
✱
56
ENHANCED ZONE PROGRAMMING See procedure later in this form and refer to the Inst. Instr.
†
Entry of a number other than one specified will give unpredictable results.
✱
58
RF JAM DETECT
[0]
0 = no RF Jam Detection; 1 = RF Jam Detect on, no CS report;
2 = RF Jam Detect on with CS report (if trouble/restore report is
enabled in fields *60, *71)