3rd Page Fields
2*05
AUTO-ARM DELAY [15]
Enter the time between the end of the arming window and
the start of auto-arming warning period, in values of 1-14
times 4 minutes 00=instant; [15=no auto arm at all]. When
this delay expires, the Auto-Arm Warrning Period begins.
2*06
AUTO-ARM WARNING PERIOD [15]
This is the time during which the user is
warned to exit the
premises prior to the auto-arming of the system (beeps
every 15 seconds; "ALERT" displayed). Enter 01-15
minutes. 00=instant at end of arming delay .
2*07
AUTO-DISARM DELAY [15]
This is the time between the end of the disarming window
and the start of auto-disarming. Enter 01-14 times 4
minutes; 00=instant at end of window; 15=no auto-disarm.
2*08
ENABLE FORCE ARM FOR AUTO-ARM [0]
0=disable; 1=enable.
2*09
OPEN/CLOSE REPORTS BY EXCEPTION [0]
1=enable; 0=disable; If enabled, only openings and closings
occurring outside the scheduled opening/closing windows
will trigger dialer reports. Opening reports will also be
suppressed during the closing window, in order to prevent
false reports when the user arms the system and then
reenters the premises to retrieve a forgotten item.
2*10
ALLOW DISARMING ONLY DURING [0]
ARMING/DISARMING WINDOWS
See system-wide field 2*11 if enabling field 2*10. This
feature adds high security to the installetion.
0=disable; 1=enable
2*18
ENABLE GOTO FOR THIS PARTITION [0]
1=Allow log-on from other partitions; 0=disable
2*20
ENABLE J7 TRIGGERS by PARTITION [1]
0=disable for displayed partition; 1=enable for displayed
partition
2*22
DISPLAY FIRE ALARMS OF [0]
OTHER PARTITIONS
0=No; 1=Yes
2*23
DISPLAY BURG/PANIC ALARMS OF [0]
OTHER PARTITIONS
10=No; 1=Yes
2*24
DISPLAY TROUBLES OF OTHER [0]
PARTITIONS
0=No; 1=Yes
4th Page Fields
3*57
BELL 2 & AUX. RELAY CONFIRM
ARM. DING
1=enable; [0=disable] Bell 2 Relay
Must be "1" for UL.
3*59
ENABLE BELL 2 & AUX. RELAY
CHIME ANNUNCIATION
1=enable; [0=disable] Bell 2 Relay
3*60
BELL 2 & AUX. RELAY TIMEOUT
| |
00-15 times 2 minutes; 00=no timeout [00,00] Bell 2 Relay
Minimum 16 min. for UL Burglary installations.
SUMMARY OF PROGRAMMING COMMANDS
To enter program mode, enter installer code + [8] + [0] +
[0]
To set standard defaults, press *97
To set communication defaults, press *94 + one of the
following: *80=low speed; *81=Ademco Express;
*82=Ademco High Speed; *83=Ademco's Contact ID
To change to next page of program fields, press *94
To return to previous set of fields, press *99
To erase account & phone number field entries, press
[*] + field number + [*]
To assign zone descriptors, press #93 + follow menu
prompts
To add custom words, press #93 + follow menu
prompts
To enter Installer's Message, press #93 + follow menu
prompts
To exit program mode, press *99 OR *98: *99 allows re-
access to programming mode by installer code. *98
prevents re-access to programming mode by installer
code.